A pump does not push liquid in from its inlet. It lowers the pressure there, and the surrounding pressure pushes the liquid in. If the pressure falls too far, the liquid boils, and that is where the trouble starts.
What cavitation is
Every liquid has a vapour pressure: the pressure below which it boils at its temperature. If the pressure at a pump's inlet drops below it, small vapour bubbles form. They are swept into higher-pressure regions of the impeller and collapse violently.
What cavitation does
It sounds like gravel in the pump. It causes vibration, pitting damage on the impeller, a loss of flow and head, and a shorter life for seals and bearings. The damage can be severe and costly.
NPSH available and required
NPSH available (NPSHa) is a property of your system: the pressure margin above vapour pressure at the pump inlet, expressed in metres of liquid. NPSH required (NPSHr) is a property of the pump, from its data sheet. NPSHa must be greater than NPSHr, usually with a margin that the pump maker or a standard specifies.
The formula
NPSHa = (P − Pv) / (ρ × g) + z_s − h_f. P is the absolute pressure on the liquid surface, Pv is the vapour pressure, z_s is the height of the liquid above the pump centreline (negative for a suction lift), and h_f is the friction loss in the suction line. Pressures must be absolute, not gauge.
Worked examples
An open tank at 101.325 kPa with 20 °C water, 2 m above the pump and 0.5 m of suction friction: NPSHa = 10.12 + 2 − 0.5 = 11.6 m.
Heat the water to 80 °C and the vapour pressure rises to about 47 kPa. The same layout now gives 7.2 m. Put the pump 3 m above the water instead (a lift) at 20 °C and it gives 6.6 m.
How to increase NPSHa
Raise the liquid level or lower the pump. Use a shorter, straighter and larger suction pipe with fewer fittings and a clean strainer. Cool the liquid. Pressurize the tank. Choose a pump with a lower NPSHr, such as a larger or slower pump.
Temperature and altitude
Warm liquids have a higher vapour pressure, which eats the margin quickly. Atmospheric pressure also falls with altitude, to about 84 kPa at 1,500 m, so a pump on a mountain site has less to start with. Use the real pressure for your location.
Common mistakes
Using gauge pressure instead of absolute. Forgetting suction friction, strainer loss or a partly closed valve. Using the wrong temperature. Comparing NPSHa with NPSHr at a different flow than the one you will run, since NPSHr rises with flow.
Try the calculators
NPSH available calculator
Check whether a pump has enough suction head to avoid cavitation.
Pump affinity laws calculator
Predict new flow, head and power after a speed or impeller change.
Pump power calculator
Estimate the power a pump needs for a given flow and head.
Pressure converter
Convert pressure between psi, bar, kPa and head of water.