Pump affinity laws calculator
Predict new flow, head and power after a speed or impeller change.
- Overall ratio
- 1.2069 (flow ∝ 1.2069, head ∝ 1.4566, power ∝ 1.75796)
- New flow
- 120.69 m³/h (531.381 US GPM)
- New head
- 43.698 m (143.366 ft)
- New shaft power
- 9.66881 kW (12.9661 hp)
Formula
Q₂ = Q₁ × r, H₂ = H₁ × r², P₂ = P₁ × r³, r = (N₂/N₁) × (D₂/D₁)Q is flow, H is head, P is power, N is speed and D is impeller diameter. The laws apply to the same pump handling the same liquid, with the efficiency assumed unchanged.
Diagram
How it is calculated
- Enter the current flow, head and power (power is optional).
- Enter the new speed, a new impeller diameter, or both.
- Work out r = (N₂ / N₁) × (D₂ / D₁).
- New flow = Q₁ × r, new head = H₁ × r², new power = P₁ × r³.
The laws describe the same pump handling the same liquid. Systems with a large static head do not follow the simple ratios, so check the pump maker's curves.
Worked examples
Speed up 1,450 to 1,750 RPM
r = 1.207. A pump giving 100 m³/h at 30 m and 5.5 kW now gives 120.7 m³/h at 43.7 m and needs about 9.67 kW.
Trim the impeller from 200 to 180 mm
r = 0.9. Flow falls to 90 m³/h, head to 24.3 m and power to 4.0 kW.
Slow the pump by 20%
Running at 1,160 RPM (r = 0.8) gives 80 m³/h at 19.2 m and needs only 2.82 kW, about half the original power. This is why variable speed drives save energy.
Key terms
- Affinity laws
- Rules that relate a pump's flow, head and power when its speed or impeller diameter changes.
- Flow (Q)
- Volume pumped per unit time. It changes in proportion to speed.
- Head (H)
- The height the pump can lift liquid. It changes with the square of speed.
- Shaft power (P)
- Power needed at the pump shaft. It changes with the cube of speed.
- Impeller trimming
- Machining an impeller smaller to lower the pump's head and flow.
- System curve
- How much head the pipe system needs at each flow. A pump runs where its curve meets it.
Assumptions and limits
Approximate. Real efficiency changes with speed, and impeller trimming is generally reliable only for modest changes, so follow the pump maker's curves. A pump must not run beyond its rated speed, power or NPSH limits. System head also changes the operating point. See the disclaimer.