NPSH available calculator
Check whether a pump has enough suction head to avoid cavitation.
Absolute, not gauge. An open tank at sea level is about 101.3 kPa.
From 1 to 99 °C.
Liquid level above the pump centreline. Use a negative value for a suction lift.
Optional. From the pump data sheet.
- NPSH available
- 11.6128 m (38.0998 ft)
- Vapour pressure at that temperature
- 2.32957 kPa abs
- Water density
- 998.21 kg/m³
Formula
NPSHa = (P_abs − P_vapour) / (ρ × g) + z_s − h_fP_abs is the absolute pressure on the liquid surface, P_vapour is the vapour pressure at the liquid temperature, z_s is the static head above the pump centreline (negative for a lift) and h_f is the friction loss in the suction line. Vapour pressure comes from the Antoine equation for water.
Diagram
How it is calculated
- Enter the absolute pressure on the liquid surface, the water temperature, the static head and the suction friction loss.
- The tool finds the water density and vapour pressure at that temperature.
- NPSHa = (P − Pv) / (ρ × g) + z_s − h_f.
- If you enter NPSHr from the pump data sheet, it shows the margin and the ratio.
Atmospheric pressure falls with altitude, so a pump at 1,500 m starts with about 84 kPa instead of 101 kPa. Enter the real value.
Worked examples
Open tank, cool water
101.325 kPa, 20 °C, level 2 m above the pump, 0.5 m of suction friction: NPSHa = 10.12 + 2 − 0.5 = 11.6 m.
Hot water at 80 °C
The vapour pressure rises to about 47 kPa, so the same layout gives only 7.17 m. Hot liquids leave much less margin.
A suction lift
If the water level is 3 m below the pump centreline (z_s = −3 m) at 20 °C with 0.5 m of friction, NPSHa falls to 6.61 m.
Key terms
- NPSHa
- Net positive suction head available: the pressure margin above vapour pressure at the pump inlet, in metres of liquid.
- NPSHr
- Net positive suction head required: the pump maker's figure for the head the pump needs to avoid cavitation.
- Cavitation
- Vapour bubbles forming in the low-pressure suction zone and collapsing violently in the impeller. It causes noise, damage and lost performance.
- Vapour pressure
- The pressure at which a liquid boils at a given temperature.
- Absolute pressure
- Pressure measured from a perfect vacuum, not from atmospheric pressure.
- Static suction head (z_s)
- The height of the liquid surface above the pump centreline. It is negative for a lift.
Assumptions and limits
Water only. Hot liquids, other fluids, dissolved gases and velocity head at the pump inlet are not covered. Pump makers and standards usually require a safety margin above NPSHr, so use their rules. See the disclaimer.