Pipe flow velocity calculator
Find how fast liquid moves through a full pipe.
- Velocity
- 1.01859 m/s
- Velocity
- 3.34184 ft/s
- Flow area
- 19.635 cm²
Formula
v = Q / A, A = π × D² / 4Q is flow rate in m³/s, D is the inside diameter in metres and v is velocity in m/s. Use the inside diameter, not the nominal pipe size.
Diagram
How it is calculated
- Convert the flow rate to cubic metres per second: L/min ÷ 60,000, m³/h ÷ 3,600, US GPM × 0.0000630902, L/s ÷ 1,000.
- Convert the inside diameter to metres.
- Find the flow area: A = π × D² / 4.
- Divide flow by area to get velocity: v = Q / A, in metres per second.
- Multiply by 3.28084 for feet per second.
Velocity depends on the diameter squared, so a small change in bore has a large effect. Recommended velocity ranges vary with the fluid, application and standard you follow, so check your own design rules.
Worked examples
A small supply line
120 L/min through a 50 mm bore. Result: Velocity: 1.01859 m/s; Velocity: 3.34184 ft/s; Flow area: 19.635 cm².
US units
100 US GPM through a 4 in pipe. Result: Velocity: 0.778188 m/s; Velocity: 2.55311 ft/s.
A narrow pipe
5 m³/h through a 25 mm bore. Result: Velocity: 2.82942 m/s; Velocity: 9.28288 ft/s.
Key terms
- Flow rate (Q)
- The volume of fluid passing a point each unit of time.
- Inside diameter (D)
- The bore of the pipe the fluid actually flows through. It is smaller than the outside diameter by twice the wall thickness.
- Nominal pipe size
- A label such as 2 inch that identifies a pipe size. It is not the exact inside diameter, which depends on the schedule or class.
- Flow area (A)
- The cross-section of the bore: the circle the fluid passes through.
- Velocity (v)
- The average speed of the fluid along the pipe. Real velocity is lower near the wall and higher at the centre.
- Continuity
- For an incompressible liquid in a full pipe, Q = A × v stays the same along the pipe, so velocity rises where the pipe narrows.
Assumptions and limits
Assumes a full pipe and steady flow. This version does not calculate friction loss or check recommended velocity limits for your fluid. Confirm critical designs with a qualified engineer. See the disclaimer.
Which diameter should I use?